mirror of
https://github.com/espressif/openthread.git
synced 2026-10-21 23:18:17 +00:00
This commit renames all nexus test files and updates corresponding configuration and source files to include a '1_1_' prefix. The '1_1' prefix represents the Thread 1.1 test plan. This change prepares the nexus test suite for the addition of tests from the Thread 1.2, 1.3, and 1.4 test plans, ensuring a clear and organized structure for multi-version specification testing. Changes include: - Renaming test_<num>.cpp to test_1_1_<num>.cpp. - Renaming verify_<num>.py to verify_1_1_<num>.py. - Updating CMakeLists.txt to reflect new test names. - Updating run_nexus_tests.sh for default tests and variants. - Updating hardcoded JSON output filenames in C++ test sources. - Updating testcase name identification in Python verification scripts.
165 lines
7.8 KiB
Python
165 lines
7.8 KiB
Python
#!/usr/bin/env python3
|
|
#
|
|
# Copyright (c) 2026, The OpenThread Authors.
|
|
# All rights reserved.
|
|
#
|
|
# Redistribution and use in source and binary forms, with or without
|
|
# modification, are permitted provided that the following conditions are met:
|
|
# 1. Redistributions of source code must retain the above copyright
|
|
# notice, this list of conditions and the following disclaimer.
|
|
# 2. Redistributions in binary form must reproduce the above copyright
|
|
# notice, this list of conditions and the following disclaimer in the
|
|
# documentation and/or other materials provided with the distribution.
|
|
# 3. Neither the name of the copyright holder nor the
|
|
# names of its contributors may be used to endorse or promote products
|
|
# derived from this software without specific prior written permission.
|
|
#
|
|
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
|
|
# AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
|
# IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
|
# ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE
|
|
# LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
|
|
# CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
|
|
# SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
|
|
# INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
|
|
# CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
|
|
# ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
|
|
# POSSIBILITY OF SUCH DAMAGE.
|
|
#
|
|
|
|
import sys
|
|
import os
|
|
|
|
# Add the current directory to sys.path to find verify_utils
|
|
CUR_DIR = os.path.dirname(os.path.abspath(__file__))
|
|
sys.path.append(CUR_DIR)
|
|
|
|
import verify_utils
|
|
from pktverify import consts
|
|
|
|
PRIMARY_CHANNEL = 11
|
|
SECONDARY_CHANNEL = 12
|
|
|
|
|
|
def verify(pv):
|
|
# 9.2.13 Energy Scan Requests
|
|
#
|
|
# 9.2.13.1 Topology
|
|
# - Two sniffers are required to run this test case!
|
|
# - Leader_2 & SED_2 formed a separate network on another channel (Secondary channel).
|
|
# - SED_2 is configured to use a short Poll Period (e.g. 500ms).
|
|
# - Router_1 & FED_1 & Commissioner joined the network on the Primary channel.
|
|
# - Commissioner & Leader_1 & Router_1 are on the same Primary channel.
|
|
#
|
|
# 9.2.13.2 Purpose & Description
|
|
# - The purpose of this test case is to verify the behavior of the DUT when receiving MGMT_ED_SCAN.qry.
|
|
#
|
|
# Spec Reference | V1.1 Section | V1.3.0 Section
|
|
# ----------------------------------------|--------------|---------------
|
|
# Collecting Energy Scan Information | 8.7.10 | 8.7.10
|
|
|
|
pkts = pv.pkts
|
|
pv.summary.show()
|
|
|
|
# Step 1: DUT
|
|
# - Description: Ensure topology is formed correctly.
|
|
# - Pass Criteria: N/A.
|
|
print("Step 1: DUT")
|
|
|
|
# Step 2: Commissioner
|
|
# - Description: Commissioner sends unicast MGMT_ED_SCAN.qry to the DUT.
|
|
# - Pass Criteria: Commissioner MUST send MGMT_ED_SCAN.qry to the DUT with the following format:
|
|
# - CoAP Request URI: coap://[DUT]:MM/c/es
|
|
# - CoAP Payload:
|
|
# - Commissioner Session ID TLV (valid)
|
|
# - Channel Mask TLV (Primary and Secondary)
|
|
# - Count TLV <0x02>
|
|
# - Period TLV <0x00c8> (200 ms)
|
|
# - Scan Duration TLV <0x20> (32 ms)
|
|
print("Step 2: Commissioner sends unicast MGMT_ED_SCAN.qry to the DUT.")
|
|
mask = (1 << (31 - PRIMARY_CHANNEL)) | (1 << (31 - SECONDARY_CHANNEL))
|
|
expected_channel_mask = '0004' + f'{mask:08x}'
|
|
pkts.filter(lambda p: p.wpan.frame_type == consts.WPAN_DATA and\
|
|
p.wpan.src16 == pv.vars['Commissioner_RLOC16'] and\
|
|
p.wpan.dst16 != 0xffff and\
|
|
p.coap.uri_path == consts.MGMT_ED_SCAN).\
|
|
must_next().\
|
|
must_verify(lambda p: p.coap.tlv.channel_mask == expected_channel_mask and\
|
|
p.coap.tlv.count == 2 and\
|
|
p.coap.tlv.period == 200 and\
|
|
p.coap.tlv.scan_duration == 32)
|
|
|
|
# Step 3: DUT
|
|
# - Description: Automatically sends a MGMT_ED_REPORT.ans response to the Commissioner.
|
|
# - Pass Criteria: The DUT MUST send MGMT_ED_REPORT.ans to the Commissioner and report energy measurements for the
|
|
# Primary and Secondary channels:
|
|
# - CoAP Request URI: coap://[Commissioner]:MM/c/er
|
|
# - CoAP Payload:
|
|
# - Channel Mask TLV (Primary and Secondary)
|
|
# - Energy List TLV (4 bytes)
|
|
print("Step 3: DUT sends a MGMT_ED_REPORT.ans response to the Commissioner.")
|
|
pkts.filter(lambda p: p.wpan.frame_type == consts.WPAN_DATA and\
|
|
p.wpan.src16 == pv.vars['Router_1_RLOC16'] and\
|
|
p.wpan.dst16 != 0xffff and\
|
|
p.coap.uri_path == consts.MGMT_ED_REPORT).\
|
|
must_next().\
|
|
must_verify(lambda p: p.coap.tlv.channel_mask == expected_channel_mask and\
|
|
len(p.coap.tlv.energy_list) == 4)
|
|
|
|
# Step 4: Commissioner
|
|
# - Description: Commissioner sends multicast MGMT_ED_SCAN.qry.
|
|
# - Pass Criteria: Commissioner MUST send MGMT_ED_SCAN.qry to the Link-Local All Thread Nodes multicast address
|
|
# (FF32:40:<MeshLocalPrefix>::1) with the following format:
|
|
# - CoAP Request URI: coap://[FF32:40:<MeshLocalPrefix>::1]:MM/c/es
|
|
# - CoAP Payload:
|
|
# - Commissioner Session ID TLV (valid)
|
|
# - Channel Mask TLV (Primary and Secondary)
|
|
# - Count TLV <0x02>
|
|
# - Period TLV <0x00c8> (200 ms)
|
|
# - Scan Duration TLV <0x20> (32 ms)
|
|
print("Step 4: Commissioner sends multicast MGMT_ED_SCAN.qry.")
|
|
pkts.filter(lambda p: p.wpan.frame_type == consts.WPAN_DATA and\
|
|
p.wpan.src16 == pv.vars['Commissioner_RLOC16'] and\
|
|
p.wpan.dst16 == 0xffff and\
|
|
p.coap.uri_path == consts.MGMT_ED_SCAN).\
|
|
must_next().\
|
|
must_verify(lambda p: p.coap.tlv.channel_mask == expected_channel_mask and\
|
|
p.coap.tlv.count == 2 and\
|
|
p.coap.tlv.period == 200 and\
|
|
p.coap.tlv.scan_duration == 32)
|
|
|
|
# Step 5: DUT
|
|
# - Description: Automatically sends a MGMT_ED_REPORT.ans response to the Commissioner.
|
|
# - Pass Criteria: The DUT MUST send MGMT_ED_REPORT.ans to the Commissioner and report energy measurements for the
|
|
# Primary and Secondary channels:
|
|
# - CoAP Request URI: coap://[Commissioner]:MM/c/er
|
|
# - CoAP Payload:
|
|
# - Channel Mask TLV (Primary and Secondary)
|
|
# - Energy List TLV (length of 4 bytes)
|
|
print("Step 5: DUT sends a MGMT_ED_REPORT.ans response to the Commissioner.")
|
|
pkts.filter(lambda p: p.wpan.frame_type == consts.WPAN_DATA and\
|
|
p.wpan.src16 == pv.vars['Router_1_RLOC16'] and\
|
|
p.wpan.dst16 != 0xffff and\
|
|
p.coap.uri_path == consts.MGMT_ED_REPORT).\
|
|
must_next().\
|
|
must_verify(lambda p: p.coap.tlv.channel_mask == expected_channel_mask and\
|
|
len(p.coap.tlv.energy_list) == 4)
|
|
|
|
# Step 6: Commissioner
|
|
# - Description: Harness verifies connectivity by instructing the Commissioner to send an ICMPv6 Echo Request to
|
|
# the DUT mesh local address.
|
|
# - Pass Criteria: The DUT MUST respond with an ICMPv6 Echo Reply.
|
|
print("Step 6: Commissioner sends an ICMPv6 Echo Request to the DUT.")
|
|
pkts.filter(lambda p: p.wpan.frame_type == consts.WPAN_DATA and\
|
|
p.wpan.src16 == pv.vars['Commissioner_RLOC16'] and\
|
|
p.icmpv6.type == consts.ICMPV6_TYPE_ECHO_REQUEST).\
|
|
must_next()
|
|
pkts.filter(lambda p: p.wpan.frame_type == consts.WPAN_DATA and\
|
|
p.wpan.src16 == pv.vars['Router_1_RLOC16'] and\
|
|
p.icmpv6.type == consts.ICMPV6_TYPE_ECHO_REPLY).\
|
|
must_next()
|
|
|
|
|
|
if __name__ == '__main__':
|
|
verify_utils.run_main(verify)
|