Accuracy Evaluation
Hypothesis testing methodology
Null hypothesis and alternative hypothesis
For a given dataset and model, the evaluated scores can be viewed as a population with mean \mu and variance \sigma. Note that the distribution is not necessarily to be a normal distribution.
When we finish implementing a model, we need to setup an accuracy reference. By evaluating the model on a subset of n samples, we practically draw n scores x_1, x_2, \dots, x_n from the population, and thus we can compute and record the sample average \bar{x} = \frac{1}{n} \sum_{i} x_i.
When testing if there is an accuracy regression, we once again evaluate the model on n samples, resulting in x'_1, x'_2, \dots, x'_n, and also sample average \bar{x'} = \frac{1}{n} \sum_{i} x'_i. The question is that, are these n samples drawn from the same distribution to the referenced one? This can be formulated as a hypothesis testing problem:
- Null Hypothesis (
H_0):x'_1, x'_2, \dots, x'_nare drawn from the same distribution to the reference. - Alternative Hypothesis (
H_1):x'_1, x'_2, \dots, x'_nare from a different distribution from the reference.
Since we care about accuracy regression only, so it should be a one-tailed hypothesis testing problem:
- Null Hypothesis (
H_0):x'_1, x'_2, \dots, x'_nare drawn from a distribution with a mean equal to or higher than the reference. - Alternative Hypothesis (
H_1):x'_1, x'_2, \dots, x'_nare drawn from a distribution with a mean lower than the reference.
Two-sample t-test
According to the two-sample t-test method, we can compute the t-statistic t = \frac{\bar{x'} - \bar{x}}{\sqrt{2 \sigma^2 / n}}. According to the Central Limit Theorem (CLT), the t-statistic is from a distribution that converges to the standard normal distribution \mathcal{N} (0, 1).
Given the threshold \gamma, the false positive (type I error) rate \alpha can be formulated as:
\begin{equation*}
\begin{aligned}
\alpha &= P \left(\bar{x'} \leq \gamma \mid t \sim \mathcal{N} (0, 1) \right) \\
&= P \left(t \leq \frac{\gamma - \bar{x}}{\sqrt{2 \sigma^2 / n}} \mid t \sim \mathcal{N} (0, 1) \right).
\end{aligned}
\end{equation*}
In practive, we setup a \alpha (e.g., 0.05) and then compute the threshold \gamma:
\begin{equation*}
\gamma = \Phi^{-1} (\alpha) \cdot \sqrt{2 \sigma^2 / n} + \bar{x}.
\end{equation*}
Note that \alpha is typically smaller than 0.5, so \gamma < \bar{x}.
Given the minimum detectable effect \theta, the false negative (type II error) rate \beta can be formulated as:
\begin{equation*}
\begin{aligned}
\beta &= P \left(\bar{x'} > \gamma \mid t \sim \mathcal{N} (-\frac{\theta}{\sqrt{2 \sigma^2 / n}}, 1) \right) \\
&= P \left(t > \frac{\gamma - \bar{x}}{\sqrt{2 \sigma^2 / n}} \mid t \sim \mathcal{N} (-\frac{\theta}{\sqrt{2 \sigma^2 / n}}, 1) \right) \\
&= P \left(t + \frac{\theta}{\sqrt{2 \sigma^2 / n}} > \frac{\gamma - \bar{x} + \theta}{\sqrt{2 \sigma^2 / n}} \mid t + \frac{\theta}{\sqrt{2 \sigma^2 / n}} \sim \mathcal{N} (0, 1) \right) \\
&= P \left(t + \frac{\theta}{\sqrt{2 \sigma^2 / n}} > \Phi^{-1} (\alpha) + \frac{\theta}{\sqrt{2 \sigma^2 / n}} \mid t + \frac{\theta}{\sqrt{2 \sigma^2 / n}} \sim \mathcal{N} (0, 1) \right)
\end{aligned}
\end{equation*}
In practice, we setup a \beta (e.g., 0.2) and then compute \theta:
\begin{equation*}
\begin{aligned}
\theta &= (\Phi^{-1} (1-\beta) - \Phi^{-1} (\alpha)) \cdot \sqrt{2 \sigma^2 / n} \\
&= - (\Phi^{-1} (\alpha) + \Phi^{-1} (\beta)) \cdot \sqrt{2 \sigma^2 / n}
\end{aligned}
\end{equation*}
Note that \alpha and \beta are typical smaller than 0.5, so \theta > 0.
References:
Steps to add accuracy tests
- Estimate
\sigmafrom the full dataset. - Decide a target minimum detectable effect
\thetabased on the nature of dataset and corresponding accuracy metric. - Decide
\alphaand\betabased on the importance of model. - Iterate sample volume
nfrom small to large, and compute\thetauntil it satisfies (is equal to or lower than) the target\theta. - Evaluate the model on the subset of sample volume
n, resulting in the reference accuracy. - The threshold