nimble/mesh: Fix Public Key mismatch error handling
Mismatch in Public Key type will cause device to send Invalid Format error, and treat any further PDU's as unexpected. This affects MESH/NODE/PROV/BI-03-C test case.
This commit is contained in:
committed by
Michał Narajowski
parent
bc67ee3966
commit
71191a5c94
@@ -47,6 +47,9 @@
|
||||
#define INPUT_OOB_NUMBER 0x02
|
||||
#define INPUT_OOB_STRING 0x03
|
||||
|
||||
#define PUB_KEY_NO_OOB 0x00
|
||||
#define PUB_KEY_OOB 0x01
|
||||
|
||||
#define PROV_ERR_NONE 0x00
|
||||
#define PROV_ERR_NVAL_PDU 0x01
|
||||
#define PROV_ERR_NVAL_FMT 0x02
|
||||
@@ -517,8 +520,8 @@ static void prov_invite(const u8_t *data)
|
||||
net_buf_simple_add_be16(buf, BIT(PROV_ALG_P256));
|
||||
|
||||
/* Public Key Type */
|
||||
/*PTS OOB*/
|
||||
net_buf_simple_add_u8(buf, 0x00);
|
||||
/* Only No OOB Public Key is supported*/
|
||||
net_buf_simple_add_u8(buf, PUB_KEY_NO_OOB);
|
||||
|
||||
/* Static OOB Type */
|
||||
net_buf_simple_add_u8(buf, prov->static_val ? BIT(0) : 0x00);
|
||||
@@ -720,7 +723,7 @@ static void prov_start(const u8_t *data)
|
||||
return;
|
||||
}
|
||||
|
||||
if (data[1] > 0x01) {
|
||||
if (data[1] != PUB_KEY_NO_OOB) {
|
||||
BT_ERR("Invalid public key value: 0x%02x", data[1]);
|
||||
prov_send_fail_msg(PROV_ERR_NVAL_FMT);
|
||||
atomic_set_bit(link.flags, LINK_INVALID);
|
||||
|
||||
Reference in New Issue