nimble/ll: Fix SCA in SyncInfo when transfering sync

SCA in SyncInfo should contain advertiser clock accuracy.
This commit is contained in:
Szymon Janc
2020-02-10 11:31:14 +01:00
parent de3521cec7
commit b8d107fb89
+1 -1
View File
@@ -2045,7 +2045,7 @@ ble_ll_sync_put_syncinfo(struct ble_ll_sync_sm *syncsm,
dptr[8] = syncsm->chanmap[4] & 0x1f;
/* SCA (3 bits) */
dptr[8] |= MYNEWT_VAL(BLE_LL_MASTER_SCA) << 5;
dptr[8] |= syncsm->sca << 5;
/* AA (4 bytes) */
put_le32(&dptr[9], syncsm->access_addr);